logo 2
  • Home
  • About Us
  • Products
    • FIBER OPTICAL CABLE
    • FIBER COMPOENT ACCESSORIES
    • FIRE ALARM CABLE
    • CONTROL & COAXIAL CABLE
    • DATA CABLE
    • NETWORK ACCESSORIES
      • PATCH PANEL
      • KEYSTONE JACK
      • FACE PLATE
      • CABLE MANAGER
    • CABINET (DATA CENTER SLOUTION )
    • HOT PRODUCTS
  • Equipment
  • Certificate
  • News
    • Company news
    • Industry news
  • Contact Us
Product was added to your cart
does fire alarm cable need to be in conduit
Home / features / does fire alarm cable need to be in conduit

does fire alarm cable need to be in conduit

Send email to us
  • Description
  • Tags
  • Comments

Description

It adheres to the tenet ,Honest, industrious, enterprising, innovative, to develop new products constantly. It regards customers, success as its own success. Let us develop prosperous future hand in hand for addressable fire alarm cable,afc fire alarm cable,aquaseal fire alarm cable, We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.


does fire alarm cable need to be in conduit
 

 

 

一、 Technical parameter

Type 1.5mm2 x2C Fire-resistant
(mm²)Specification 1×1.38mm
Voltage rating (V) 300
                                                  Conductor
Conductor material BC
Conductor size (mm) 1/1.38±0.003
Wrapping tape
Wrapping tape material Synthetic mica tape (layer two)
Insulation
Insulation material Ceramic polyolefin
Insulation diameter(mm) 3.85±0.1
Average Thickness (mm) 0.8
Insulation Identification brown、blue
                                                laying-up
lay (mm) 150±10
Shield
Drain wire(mm) 1/0.8±0.003 TC
Shield Single sided aluminum
                                                 Jacket
Jacket material LSZH
Jacket Diameter(mm) 10.0±0.3
Average Thickness (mm) 1.0
                                           Electrical Properties at 20℃
conductor dc resistance (ohm/km) ≤12.1
Insulation resistance(MΩ*km) ≥1000

 

 

 

 
abide by the contract ,, conforms to the market requirement, joins in the market competition by its high quality as well as provides more comprehensive and excellent service for clients to let them become big winner. The pursue of the company, is the clients, satisfaction for does fire alarm cable need to be in conduit, If you have any comments about our company or products, please feel free to contact us, your coming mail will be highly appreciated.

Tags: fiber optic cable connector types, fiber optic cable datasheet, indoor outdoor plenum fiber optic cable, network cabinet accessories, network cabinet air filter
  1. 评分 / 5

    – 2019-03-18 22:16:44

    Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
  2. 评分 / 5

    – 2019-01-25 18:56:45

    The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.

Send your message to us:








Please prove you are human by selecting the Car.




Related products

  • Unitube Steel Tape Armoring Gyxtw 12 Core Sm Fiber Optic Cable Telecom Communication Cable

    Read more
  • Feeder cable 1/2" Superflexible Coaxial Cable Telecom RF Feeder Cable

    Read more
  • Low Loss 50Ohm RF Telecom Feeder Cable

    Read more

Products

  • FIBER OPTICAL CABLE
  • FIBER COMPOENT ACCESSORIES
  • FIRE ALARM CABLE
  • CONTROL & COAXIAL CABLE
  • DATA CABLE
  • NETWORK ACCESSORIES
    • PATCH PANEL
    • KEYSTONE JACK
    • FACE PLATE
    • CABLE MANAGER
  • CABINET (DATA CENTER SLOUTION )
  • HOT PRODUCTS
  • features

Latest News

  • How to lay the network cable in the integrated wiring system? 2019-06-13
  • St/ST single mode fiber patch cord application? 2019-05-30
  • How does the network cable pick up the network cable at home? How much does it cost to install a network cable? 2019-05-30

Contact Us

2. 4th Floor ,Longhua Car Plaza,Huanan Road,Minzhi Community Longhua New District Shenzhen China
0086-574-56798032
0086-574-26886033
Floweryuki@hotmail.com

Follow Us

Facebook
Twitter
Google+
LinkedIn

Copyright © Lianjiang All Rights Reserved     sitemap