Flat Drop Fiber Optic Cable Specification

1. Cable Description

Flat FTTH put in side with 2 FRP, the optical fiber unit positioned in the Loose tube. Two parallel strength member are placed at the two sides and have loose tube to protect the inside FTTH, outside sheath is PE.

2. Cable Drawing


Note : Structure drawing just for reference, please check the following details.

3. Application

1.Adopted to cabling.
2.Suitable for aerial and duct drop installation
3.Long distance and local area network communication.

4. Characteristics

1. Good mechanical and environment characteristic
2. Anti-UV characteristic meet the requirements of relevant standards
3. The mechanical characteristic meet the requirements of relevant standards
4. Big capacity data transmission
5. Meet various requirements of market and clients

5. Features:

         Items  Description
Number of fiber 2~24 cores
Fiber type G652D/G657A/G657B/G655
Strength member material FRP
diameter 1.0±0.1mm
Loose tube material PBT
diameter (1~12)2.0~24:3.0mm
Out sheath material PE
Color Black
Cable size (Height * width) 4.0±0.5×7.0±0.5mm
Cable weight 36KG±2KG

6. Standard color of fiber and tube
The color of the individual fibers, shall be in accordance with the table as below:

Standard Color Identification
No. 1 2 3 4 5 6
Color Blue Orange Green Brown Slate White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua

When the fibers are over 12, the 13-24 fibers will be marked with a black tracer, the black fiber will be marked with white tracer. The tracer should be marked on the fiber surface with a interval.

7. Cable Mechanical characteristic

Items Description
Installation Temperature range -20–+60℃
Operation and transport temperature -40-+70℃
Min Bending Radius(mm) Long term 15D
short term 30D
Allowable Tensile Strength(N) Long term 1000
short term 2000
Crush Load (N/100mm) Long term 600
short term 1200
Recommended Span (m) 60±10KG

8. Requirement for Order:

1.Fiber sort: Single mode G652,G655,G657, Multi mode 50/125,62.5/125,OM3,OM4.
2.Fiber brand: YOFC, Corning, Fiberhome Fujikura, OFS etc.
3.Sheath material: PE,LSZH, PVC( can be required).
4.Sheath color: Black ,can be required.
5.The fiber and tube color: according to stranded color, can be required.
6.The cable Size: shall be in accordance with the table, can be required.
7.Length of cable: generally is 2KM, can be required.
8.Other requirement:can be negotiated.

9. Fiber characteristic

Fiber style Unit SM

G652D

SM

G657A1

SM

G657A2

condition nm 1310/1550 1310/1550 1310/1550
attenuation dB/km ≤0.36/0.22 ≤3.5/0.21 ≤3.5/0.21
Dispersion 1310nm Ps/(nm*km) ≤18 ≤18 ≤18
1550nm Ps/(nm*km) ≤22 ≤22 ≤22
Zero dispersion wavelength nm 1312±10 1312±10 1300-1324
Zero dispersion slope ps/(nm²×Km) ≤0.091 ≤0.090 ≤0.092
PMD Maximum Individual Fiber [ps/√km] ≤0.2 ≤0.2 ≤0.2
PMD Design Link Value ps/(nm²×Km) ≤0.08 ≤0.08 ≤0.08
Fiber cutoff wavelength λc nm ≧1180,≤1330 ≧1180,≤1330 ≧1180,≤1330
Cable cutoff wavelength λcc nm ≤1260 ….. …..
MFD 1310nm um 9.2±0.4 9.0±0.4 9.8±0.4
1550nm um 10.4±0.8 10.1±0.5 9.8±0.5
Step(mean of bidirectional measurement) dB ≤0.05 ≤0.05 ≤0.05
Irregularities over fiber length and point discontinuity dB ≤0.05 ≤0.05 ≤0.05
Difference backscatter coefficient dB/km ≤0.03 ≤0.03 ≤0.03
Attenuation uniformity dB/km ≤0.01 ≤0.01 ≤0.01
Cladding diameter um 125.0±0.1 124.8±0.1 124.8±0.1
Cladding non-circularity % ≤1.0 ≤0.7 ≤0.7
Coating diameter um 242±7 242±7 242±7
Coating/chaffinch concentrically error um ≤12.0 ≤12.0 ≤12.0
Coating non circularity % ≤6.0 ≤6.0 ≤6.0
Core/cladding concentricity error um ≤0.6 ≤0.5 ≤0.5
Curl(radius) um ≥4 ≥4 ≥4
Fiber style Unit SM

G652D

SM

G657A1

SM

G657A2

condition nm 1310/1550 1310/1550 1310/1550
attenuation dB/km ≤0.36/0.23 ≤3.5/0.21 ≤3.5/0.21
Dispersion 1310nm Ps/(nm*km) ≤18 ≤18 ≤18
1550nm Ps/(nm*km) ≤22 ≤22 ≤22
Zero dispersion wavelength nm 1312±10 1312±10 1300-1324
Zero dispersion slope ps/(nm²×Km) ≤0.091 ≤0.090 ≤0.092
PMD Maximum Individual Fiber [ps/√km] ≤0.2 ≤0.2 ≤0.2
PMD Design Link Value ps/(nm²×Km) ≤0.08 ≤0.08 ≤0.08
Fiber cutoff wavelength λc nm ≧1180,≤1330 ≧1180,≤1330 ≧1180,≤1330
Cable cutoff wavelength λcc nm ≤1260 ….. …..
MFD 1310nm um 9.2±0.4 9.0±0.4 9.8±0.4
1550nm um 10.4±0.8 10.1±0.5 9.8±0.5
Step(mean of bidirectional measurement) dB ≤0.05 ≤0.05 ≤0.05
Irregularities over fiber length and point discontinuity dB ≤0.05 ≤0.05 ≤0.05
Difference backscatter coefficient dB/km ≤0.03 ≤0.03 ≤0.03
Attenuation uniformity dB/km ≤0.01 ≤0.01 ≤0.01
Cladding diameter um 125.0±0.1 124.8±0.1 124.8±0.1
Cladding non-circularity % ≤1.0 ≤0.7 ≤0.7
Coating diameter um 242±7 242±7 242±7
Coating/chaffinch concentrically error um ≤12.0 ≤12.0 ≤12.0
Coating non circularity % ≤6.0 ≤6.0 ≤6.0
Core/cladding concentricity error um ≤0.6 ≤0.5 ≤0.5
Curl(radius) um ≥4 ≥4 ≥4
G657A1  fiber Environmental Characteristics   (1310nm, 1500nm, &1625nm)
Temperature dependence Induced attenuation at -60℃ to +85℃ ≤0.05 [db/Km]
Temperature-humidity cycling

Induced attenuation at

 -10℃ to +85℃,
98% RH
≤0.05 [db/Km]
Watersoak dependence Induced attenuation at  23℃ for 30 days ≤0.05 [db/Km]
Damp heat dependence

Induced attenuation at

 85℃ and 85% RH ≤0.05 [db/Km]
 for 30 days
Dry heat aging at  85℃ ≤0.05 [db/Km]
Mechanical Specification
Proof  test off  line ≧9.0 [N]
≧1.0 [%]
≧100 [kpsi]
Macro-bend induced attenuation
100 turns around a mandrel of 50 mm dimeter
10 turns around a mandrel of 30 mm dimeter 1550nm ≤0.1 [dB]
10 turns around a mandrel of 30 mm dimeter 1625nm ≤0.3 [dB]
1 turn around a mandrel of 20 mm diameter 1550nm ≤0.1 [dB]
1 turn around a mandrel of 20 mm diameter 1625nm ≤0.5 [dB]
Coating strip force typical average force 1.7 [N]
peak force ≧1.3 ≤8.9 [N]
Daynamic stress corrosition susceptibility parameter nd(typical) ≧20
G657A2 fier Environmental Characteristics   (1310nm, 1500nm, &1625nm)
Temperature dependence Induced attenuation at -60℃ to +85℃ ≤0.05 [db/Km]
Temperature-humidity cycling

Induced attenuation at

 -10℃ to +85℃,
98% RH
≤0.05 [db/Km]
Watersoak dependence Induced attenuation at  23℃ for 30 days ≤0.05 [db/Km]
Damp heat dependence

Induced attenuation at

 85℃ and 85% RH ≤0.05 [db/Km]
 for 30 days
Dry heat aging at  85℃ ≤0.05 [db/Km]
Mechanical Specification
Proof  test off  line ≧9.0 [N]
≧1.0 [%]
≧100 [kpsi]
Macro-bend induced attenuation
10 turns around a mandrel of 30 mm dimeter 1550mm ≤0.3 [dB]
10 turns around a mandrel of 30 mm dimeter 1625mm ≤0.1 [dB]
1 turns around a mandrel of 20 mm dimeter 1550nm ≤0.1 [dB]
1 turns around a mandrel of 20 mm dimeter 1625nm ≤0.2 [dB]
1 turn around a mandrel of 15 mm diameter 1550nm ≤0.5 [dB]
1 turn around a mandrel of 15 mm diameter 1625nm ≤1.0 [dB]
Coating strip force typical average force 1.7 [N]
peak force ≧1.3 ≤8.9 [N]
Daynamic stress corrosition susceptibility parameter nd(typical) ≧20

10. Cable marking

The cable sheath shall be marked with white characters at intervals of one meter with following information:
1. Purchaser’s name
2. Fiber type and counts
3. Cable type
4. Length marking

10.2 Cable reel:
1. Cable type/size
2. Length of cable in meters
3. Cable weight

11. Packing Information
1. Packing material: Wooden drum
2. Packing length: standard length of cable shall be 1 km. Other cable length is also available if required by customer

12. Our certificates :
1) ISO9002
2) SGS, ROHS
3) ULE329066
4) REACH

13. Testing Lab:

No Device name No Device name
1 Optical time domain reflectometer (OTDR) 8 GNZV Cable Torsion Testing Machine
2 Fiber Polarization Mode Dispersion 9 GQNV Cable Flexing Testing Machine
3 Fiber Dispersion ,Strain Tester 10 GJRV Cable Winding Testing  Machine
4 High Low Temperature Test Chamber 11 GZDV Cable Vibration Testing Machine
5 Cable Impact Testing Machine               12      Cable Water Penetration Test
6 Cable Squash Tensile Testing Machine               13               Fusion Splicer
7               GWQV Cable Bending Tester 14 Cable Water Penetration Test Rig

Fiber Optic Cable Mechanical Performance Testing Laboratory

1. Main Testing Type: Precision Test and Mechanical Test.
2. Precision Testing Machine: EXFO OTDR, EG&G PMD-440,CD-400.
3. Mechanical Performance Testing : Temperature, Impact, Tensile, Bending, Torsion, Flexing, Winding, Vibration, Water Penetration, Fusion Splicer, Water Penetration.
So a comprehensive testing are available.

14. Our advantages:

1. Professional cable manufacturer.
2. About 10 years experiences in cable industry.
3. MOQ just 1Km.
4. ISO, UL , ROSH,REACH…certifications.
5. Can be customized production of fiber optic cable.
6. Independent Lab with full set of testing machines.
7. OEM for 3M , TYCO more than 5 years.
8. Supply to Thai telecom, Doha airport, Doha telecom, Dubai telecom, Dubai telecom ,Slovenia telecom and Yemen telecom and other big projects.

  1. 评分 / 5

    – 2019-04-14 05:16:52

    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
  2. 评分 / 5

    – 2019-02-04 16:19:41

    The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.

Send your message to us:








Please prove you are human by selecting the Plane.




Related products

  • Dielectric Loose Tube Cable-GYFTY

    Read more
  • Non-metal center beam tube outdoor optical cable-GYFXTY

    Read more
  • Aluminum Tape Armored Fiber Optic Cable For Aerial And Duct-GYTA

    Read more

Products

  • FIBER OPTICAL CABLE
  • FIBER COMPOENT ACCESSORIES
  • FIRE ALARM CABLE
  • CONTROL & COAXIAL CABLE
  • DATA CABLE
  • NETWORK ACCESSORIES
    • PATCH PANEL
    • KEYSTONE JACK
    • FACE PLATE
    • CABLE MANAGER
  • CABINET (DATA CENTER SLOUTION )
  • HOT PRODUCTS
  • features

Latest News

  • How to lay the network cable in the integrated wiring system? 2019-06-13
  • St/ST single mode fiber patch cord application? 2019-05-30
  • How does the network cable pick up the network cable at home? How much does it cost to install a network cable? 2019-05-30

Contact Us

2. 4th Floor ,Longhua Car Plaza,Huanan Road,Minzhi Community Longhua New District Shenzhen China
0086-574-56798032
0086-574-26886033
Floweryuki@hotmail.com

Follow Us

Facebook
Twitter
Google+
LinkedIn

Copyright © Lianjiang All Rights Reserved     sitemap